Sign In | Join Free | My benadorassociates.com
China CANGZHOU FUTURE INDUSTRY CO.,LTD logo
CANGZHOU FUTURE INDUSTRY CO.,LTD
Best Price Hight quality Fast Delivery
Verified Supplier

2 Years

Home > Fire Extinguisher Aerosol Actuator >

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Product Categories
CANGZHOU FUTURE INDUSTRY CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Brand Name : FUTURE

Place of Origin : CHINA

MOQ : 100000SET

Price : Negotiable

Payment Terms : TT,LC,D/A,D/P

Supply Ability : 10,000,000 sets per month

Delivery Time : 5-20 work days

Packaging Details : CARTON

Product Name : Fire Extinguisher accessories

Used : Liquid And Powder

Stem Material : Plastic

Cup Material : Tinplate

Size : One Inch

High Light : Fire Extinguisher Pressure Gauge, Reliable Fire Extinguisher Pressure Gauge, Accurate Fire Extinguisher Pressure Gauge

Contact Now

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Product Description:

Speed saves lives. This Quick-Release Safety Male Fire Extinguisher Valve is engineered for the fastest possible deployment in an emergency. Featuring an intuitive, positive-action puncture lever instead of a traditional handwheel, this valve assembly allows an operator to discharge the extinguisher with a single, swift motion. The design eliminates the valuable seconds lost in turning a stiff or frozen handwheel. The lever is guarded to prevent accidental discharge but remains easily accessible. Despite its speed-focused design, it incorporates all standard safety features, including a tamper seal and a reliable pressure gauge. This male thread valve is ideal for high-traffic public spaces, vehicles, and industrial sites where reducing response time is a critical factor in fire safety outcomes.

Bullet Points:

  • Positive-action puncture lever for instant activation without turning.

  • Guarded lever design prevents accidental operation.

  • Rapid-deployment valve assembly for critical emergency response.

  • Maintains standard safety features like a tamper seal and pressure gauge port.

  • The fast-action male thread valve for high-risk or high-traffic environments.

Specific Application Scenario
This valve is used on fire extinguishers mounted in race car cockpits or on the walls of a busy school corridor, where intuitive and immediate operation is paramount.

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design

Factory Production Floor
A dedicated line assembles these valves with a focus on the precision of the lever mechanism. Each valve is tested for both its seal integrity and the smooth, positive action of the release lever.

Packing and Transportation
Valves are packed in boxes that clearly illustrate the quick-release lever mechanism. They are often shipped with a protective cap over the lever to prevent damage during transit.

FAQ

  • Q: How does the quick-release mechanism work on this safety valve?
    A: Pulling the lever drives an internal pin that instantly punctures a gas cartridge or opens the main valve seal, allowing for immediate agent flow.

  • Q: Is this valve assembly more prone to accidental discharge?
    A: No, the lever is designed with a safety clip or requires a significant amount of force to overcome a detent, making it very resistant to accidental bumps.

  • Q: Can this male thread valve be recharged after use?
    A: Yes, like a standard valve, the entire extinguisher must be sent for professional servicing where the valve will be reset and the system recharged.

  • Q: What is the maintenance procedure for the quick-release mechanism?
    A: It should be visually inspected monthly for damage and the tamper seal verified. An operational test (discharge) should only be performed during formal servicing.

  • Q: Is this design suitable for all types of fire extinguishers?
    A: It is most common and effective on dry chemical and water-based stored-pressure extinguishers.


Product Tags:

Valve adapters for fire extinguishers

      

Fire extinguisher valve fittings and couplings

      

Valve assemblies for fire suppression equipment

      
Quality Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design for sale

Quick-Release Safety Male Fire Extinguisher Valve for Rapid Emergency Response with Puncture Lever Design Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: CANGZHOU FUTURE INDUSTRY CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)